| JNT - EVC11 | |||
| Kiwango cha Mkoa | |||
| Kiwango cha Mkoa | NA Standard | Kiwango cha EU | |
| Uainishaji wa Nguvu | |||
| Voltage | 208–240Vac | 230Vac±10% (Awamu moja) | 400Vac±10% (Awamu tatu) |
| Nguvu / Amperage | 3.5kW / 16A | - | 11kW / 16A |
| 7kW / 32A | 7kW / 32A | 22kW / 32A | |
| 10kW / 40A | - | - | |
| 11.5kW / 48A | - | - | |
| Mzunguko | 50-60Hz | 50-60Hz | 50-60Hz |
| Kazi | |||
| Uthibitishaji wa Mtumiaji | RFID (ISO 14443) | ||
| Mtandao | LAN Standard (Hiari ya Wi-Fi yenye Malipo ya Ziada) | ||
| Muunganisho | OCPP 1.6 J | ||
| Ulinzi na Kawaida | |||
| Cheti | ETL na FCC | CE (TUV) | |
| Kiolesura cha Kuchaji | SAE J1772, Aina ya 1 Plug | IEC 62196-2 , Soketi ya Aina ya 2 au Plug | |
| Kuzingatia Usalama | UL2594 , UL2231-1/-2 | IEC 61851-1 , IEC 61851-21-2 | |
| RCD | CCID 20 | AinaA + DC 6mA | |
| Ulinzi Nyingi | UVP , OVP , RCD , SPD , Ulinzi wa Makosa ya Chini , OCP , OTP , Dhibiti Ulinzi wa Makosa ya Majaribio | ||
| Kimazingira | |||
| Joto la Uendeshaji | -22°F hadi 122°F | -30°C ~ 50°C | |
| Ndani / Nje | IK08, ua wa Aina ya 3 | IK08 & IP54 | |
| Unyevu wa Jamaa | Hadi 95% kutopunguza | ||
| Urefu wa Cable | 18ft (5m) Kawaida , 25ft (7m) Hiari pamoja na Ada ya Ziada | ||
Lenga kutoa suluhu za mong pu kwa miaka 5.